Goodsense Cushion Tire LPG&Gasoline Forklift advantages:
- Shorter wheelbase with smaller turning radius with more flexibility.
- Cushion tire to work at smooth pavement, does not require too much pavement friction
- for indoor works with less noise and less emission in contrast with diesel forklift
- EPA tier 4 compliance
General
Model
FY20D1
Power Type
LPG
Load Capacity
kg
2000
Load centre
mm
500
Tyre
Tyre
Cushion Tyre
Front Tyre
21x7x15
Rear Tyre
16(1/4)x6x11(1/4)
Overall Dimension
Lift Height
mm
3000
Fork Size
L×W×T
mm
1070*120*40
Mast Tilt Angle
F/R
.
6/12
Mast Lowered Height
mm
2070
Mast Extended Height(with backrest)
mm
4070
Length to face of fork(Without fork)
mm
2360
Overall Width
mm
1110
Cabin Height
mm
2080
Loading Plane Height
mm
3000
Application Area:
1.Warehouse
2.Port
3.Factory
4.Distribution Center
5.Logistics
If you have any other questions,please contact us directly.Our forklift are all with high quality,and you can choose any other engine to equip.It can be produced according to your idea.And we invite you to visit our factory.
Cushion Tire LPG&Gasoline Forklift Gasoline Forklift,Forklift With Quadruple Mast,Cushion Tire Lpg Forklift ZHEJIANG GOODSENSE FORKLIFT CO.,LTD , https://www.goodsenseforklift.com
1. Lightning strike lightning protection mainly uses lightning rods, nets, belts and good grounding systems. Its purpose is to protect buildings from lightning damage and provide a relatively safe environment for people or equipment in buildings.
This part of the general substation has been built at the time of construction and usually does not need to be considered.
2. Induction of lightning protection Currently, there are two main ways for lightning-induced high voltage damage to communication equipment:
Radiated induced lightning strikes are strong lightning electromagnetic fields that cause equipment damage through radiation or induction.
Induced lightning high voltage pulses transmitted from various lines by power supply lines, signal lines, and control lines damage the electronic devices.
Therefore, the corresponding measures taken are:
· Take electromagnetic shielding measures.
Install surge protectors, including power supply systems and signal systems.
· Equipotential processing.
Good grounding.
Substation communication room lightning protection program (2)
In order to protect various types of equipment in buildings and buildings from lightning damage or minimize lightning damage, integrated lightning protection is now adopted. The comprehensive lightning protection design plan should include two aspects: the protection against direct lightning strikes and the protection against induced lightning strikes. The lack of any aspect is incomplete, flawed and potentially dangerous.