How to operate and debug the cardboard crack tester

How to operate and debug the paperboard cracking tester? This equipment is difficult to operate for people who do not normally use it, and it is easy to have problems if some details are not noticed, because the user must buy a paperboard cracking tester. Should be strictly in accordance with the dump instructions, or in accordance with the technical personnel's instructions to operate, for this reason, dump technology Xiaobian made the following analysis and analysis of this problem:

First, the operation process

2, in the case of ensuring that there is no problem with glycerin and the entire equipment

3, first put the sample into the pressure plate

4, the pressure on the semi-manual way to press down the pressure plate

5, look at the pointer on the pressure gauge between seven and ten, press the sample

Second, the debugging process

1. After pressing the clear key, press the peak key again

2, then grab the pressure bar with your right hand

3, left hand into the platen sample to induce the rupture of the sample

4, both hands are placed in the designated position

5, the right hand to force the pressure lever to the left pull

6, then observe the numerical changes on the display

7, at the same time pay attention to the left hand on the sample induction test sample is not broken

8, at the same time the top of the broken to release the pressure rod

9, which is to pull the pressure bar to the right

10. Two to three seconds to release the pressure rod at the moment of breaking the test specimen

Third, analysis of common problems

1, after breaking the rubber mold, many people think that after replacing the rubber mold on it

The technical engineer answers:

1, this is wrong, because when breaking the rubber mold, there may be some air into the glycerol system, so the value of the words may be inaccurate, and the rubber mold is always concave

2. Normally, the rubber mold must be bulging. When it is pressed by hand, it is sunken. When it is released, it will return to its original position.

2. How can the air in glycerol be discharged?

The technical engineer answers:

1, first start the device

2, the right hand to grasp the pressure rod

3, pressurize equipment

4, at the same time observe the rubber mold up

5, when the rubber mold up to a certain height

6, that is, when the rubber mold up and down the pressure plate is 1.5 cm high

7, left-hand press the stop button

8, the right hand can not release the pressure rod

9, after pressing the stop button, left hand to loosen the screw on the cup

10. Always take the screw out

11, then press the start button, while releasing the right hand

12. At this time, the equipment will be venting air, and at the same time, the glycerin in the oil cup will also be seen falling.

3, if this is not enough to blow up the rubber mold?

The technical engineer answers:

1, repeated according to the previous operation more than a few can be

2. Remember to be sure to twist the screw back when doing the next air exhaust

3, to be out of the oil in the cup.

How to operate and debug the cardboard cracking tester? Through the detailed introduction of the above problems, I believe that the user should know how to operate and debug the cardboard cracking tester. If there are other questions, you can contact the tilting technician directly.

Our  shearing machines are offered as per your requirement. our company has achieved great success in providing customer Services from all over the world with excelent machines featuring high technical content, optimized composition, reliable performance and easy operation. We are committed to providing quility machines for all customers with dedicated after-sales services.

Shearing Machine

Shearing Machine,Hydraulic Guillotine Shearing Machine,Foot Operated Shear Machine,Pedal Shearing Machine

Botou Kaiyite Cold Bending Machinery Co.,Ltd. , https://www.chinacoldbendingmachinery.com